Limited Loose Flange Expansion Joint · VSSJA-2 (B2F)
Double Flange Expansion Joint
Takes the axial expansion and contraction of a straight pipe between two anchors, and gives you room to fit valves and pumps. Limit studs stop it pulling apart — the anchors, not the joint, hold the pressure thrust.
- Size Range:DN65–DN3600 (2½"–144")
- Pressure:PN6 / PN10 / PN16; PN25 on request
- Axial stroke: ΔL 50–140 mm, by size
- Body: Q235 carbon steel, ductile iron or stainless steel
- Gasket: NBR; EPDM for drinking water
- Drilling: DIN, EN 1092-1, ASME B16.5 / B16.47, JIS, AS
- Limit studs: Outside nuts set at the end of the stroke
Double Flange Expansion Joint Dimensions
PN16 flanges (EN 1092-1, same drilling as GB/T 9124.1 and DIN). All dimensions in mm. L is the installation length at half stroke; ΔL is the total axial stroke.
Swipe the table →
| DN | Inch | Length and stroke | Flange PN16 (EN 1092-1 = GB = DIN) | Bolts | ||||
|---|---|---|---|---|---|---|---|---|
| L | Stroke ΔL | L min – max | OD | Bolt circle | Holes | |||
| 65 | 2½" | 340 | 50 | 315 – 365 | 185 | 145 | 8 × Ø18 | M16 |
| 80 | 3" | 340 | 50 | 315 – 365 | 200 | 160 | 8 × Ø18 | M16 |
| 100 | 4" | 340 | 50 | 315 – 365 | 220 | 180 | 8 × Ø18 | M16 |
| 125 | 5" | 340 | 50 | 315 – 365 | 250 | 210 | 8 × Ø18 | M16 |
| 150 | 6" | 340 | 50 | 315 – 365 | 285 | 240 | 8 × Ø22 | M20 |
| 200 | 8" | 340 | 50 | 315 – 365 | 340 | 295 | 12 × Ø22 | M20 |
| 250 | 10" | 340 | 50 | 315 – 365 | 405 | 355 | 12 × Ø26 | M24 |
| 300 | 12" | 350 | 65 | 317.5 – 382.5 | 460 | 410 | 12 × Ø26 | M24 |
| 350 | 14" | 350 | 65 | 317.5 – 382.5 | 520 | 470 | 16 × Ø26 | M24 |
| 400 | 16" | 350 | 65 | 317.5 – 382.5 | 580 | 525 | 16 × Ø30 | M27 |
| 450 | 18" | 350 | 65 | 317.5 – 382.5 | 640 | 585 | 20 × Ø30 | M27 |
| 500 | 20" | 350 | 65 | 317.5 – 382.5 | 715 | 650 | 20 × Ø33 | M30 |
| 600 | 24" | 350 | 65 | 317.5 – 382.5 | 840 | 770 | 20 × Ø36 | M33 |
| 700 | 28" | 350 | 65 | 317.5 – 382.5 | 910 | 840 | 24 × Ø36 | M33 |
| 800 | 32" | 590 | 130 | 525 – 655 | 1025 | 950 | 24 × Ø39 | M36 |
| 900 | 36" | 590 | 130 | 525 – 655 | 1125 | 1050 | 28 × Ø39 | M36 |
| 1000 | 40" | 590 | 130 | 525 – 655 | 1255 | 1170 | 28 × Ø42 | M39 |
| 1200 | 48" | 590 | 130 | 525 – 655 | 1485 | 1390 | 32 × Ø48 | M45 |
| 1400 | 56" | 590 | 130 | 525 – 655 | 1685 | 1590 | 36 × Ø48 | M45 |
| 1600 | 64" | 590 | 130 | 525 – 655 | 1930 | 1820 | 40 × Ø56 | M52 |
| 1800 | 72" | 590 | 130 | 525 – 655 | 2130 | 2020 | 44 × Ø56 | M52 |
| 2000 | 80" | 590 | 130 | 525 – 655 | 2345 | 2230 | 48 × Ø62 | M56 |
| DN2200 – DN3600 (PN10 / PN6) and the full PN6 / PN10 / PN25 tables are in the datasheet below. | ||||||||
DN2200 – DN3600 (PN10 / PN6) and the full PN6 / PN10 / PN25 tables are in the datasheet below.
Longer stroke and other lengths on request.
How It’s Built
Six parts. The gasket seals while the spigot slides; the limit studs set how far it can open.

- 1. Body: — Flanged sleeve with a gasket chamber. Q235 steel, ductile iron or stainless steel.
- 2. Gasket: — Wedge-section NBR ring (EPDM for drinking water). The spigot slides through it while it keeps sealing.
- 3. Gland: — Ring that presses the gasket into the cham
- 4. Limit spigot — Steel pipe with a welded flange. Moves in and out with the pipe.
- 5. Gland studs: — Set the gasket compression. Tighten evenly; the spigot must still slide.
- 6. Limit studs and nuts: — Long studs between the body and the spigot flange. The outside nuts are set at the end of the stroke, so the joint cannot pull apart.
Expansion Joint or Dismantling Joint?
Built like our dismantling joint, but longer and with limit studs instead of tie studs. It moves — so the pipe needs anchors.
Swipe the table →
| Double flange expansion joint | Double flanged dismantling joint | |
|---|---|---|
| Rods | Limit studs; the outside nuts are set at the end of the stroke | Long tie studs through both end flanges and the gland, nuts locked at every flange |
| Pressure thrust | Must be held by pipe anchors | Carried by the tie studs |
| Movement in service | Axial stroke ΔL, 50–140 mm by size | None once locked — works as a rigid spool |
| At installation | Pulled to half stroke, then limit nuts set | Adjusted within ΔL (40–80 mm), then locked |
| Installation length L | 340–600 mm | 200–450 mm |
| Anchors at the joint | Needed on both sides | Not needed for the thrust |
| Main job | Taking expansion and contraction of straight runs | Fitting and removing valves, pumps and meters |
Choose a dismantling joint when
- Temperature: the pipe length changes with the seasons or the process
- Anchors: there is an anchor on each side
- Direction: movement is along the axis only
Choose an expansion joint when
- Service: you only need to remove a valve or pump
- No anchor: nothing near the valve can take the thrust
- Rigid: the line must not move
Materials, Gasket and Coating
Standard materials are below. Tell us the medium and where the pipe runs, and we match the gasket and finish.
| Part | Standard | Options |
|---|---|---|
| Body and gland | Q235 carbon steel | Ductile iron QT400-15; cast steel ZG230-450; 20# steel; SS304 / SS316L |
| Flanged spigot | Q235 steel pipe + flange | 20# or Q355 (16Mn) steel; SS304 / SS316L |
| Gasket | NBR | EPDM (drinking water); other rubbers on request |
| Studs and nuts | Q235 / 35# carbon steel, zinc plated | Stainless steel 304 / 321 (1Cr18Ni9Ti) |
| Coating | Epoxy, blue | Red epoxy; hot-dip galvanising; no coating on stainless joints |
NBR gasket (standard)
For: water, sewage, oil, fuel, low-pressure gas.
Temperature: −10 to +80 °C
Not for: lines that need a drinking-water rubber.
EPDM gasket
For: drinking water, hot water, sea water.
Temperature: −20 to +90 °C
Not for: oil and fuel.
Finish
Blue or red epoxy: buried lines, valve chambers, pump houses.
Stainless steel: sea water and chemical plants.
Galvanised: outdoor pipework.
The gasket is the only rubber part. Choose it by the medium; choose the finish by where the joint is installed.
Pressure and Temperature
Choose the class by working pressure. Every joint is hydrostatically tested before coating.
Pressure classes
| Class | Working pressure | Shell test (1.5×) | Seal test (1.1×) |
|---|---|---|---|
| PN6 | 0.6 MPa | 0.9 MPa | 0.66 MPa |
| PN10 | 1.0 MPa | 1.5 MPa | 1.1 MPa |
| PN16 | 1.6 MPa | 2.4 MPa | 1.76 MPa |
| PN25* | 2.5 MPa | 3.75 MPa | 2.75 MPa |
* PN25 on request.
Temperature
−10 to +80 °C with the standard NBR gasket; EPDM up to +90 °C on water.
Media
Water, drinking water, sea water, sewage, oil; gas at low pressure.
Pressure class by size
| Size | Standard class |
|---|---|
| DN65 – DN1000 | PN16 (PN25 on request) |
| DN1200 – DN2000 | PN16 |
| DN2200 – DN3000 | PN10 |
| DN3200 – DN3600 | PN6 |
The pressure class sets the body and flange thickness. The thrust on the anchors grows with pressure — see the anchor load table below.
How Much Stroke, How Strong the Anchors
Two numbers to check before you order: the movement of your pipe, and the force your anchors must hold.
Movement calculator
Anchor load from pressure thrust (kN)
| Size | PN10 | PN16 | PN25 |
|---|---|---|---|
| DN100 | 10 | 16 | 26 |
| DN150 | 22 | 36 | 56 |
| DN200 | 38 | 60 | 94 |
| DN300 | 83 | 133 | 207 |
| DN400 | 143 | 228 | 356 |
| DN500 | 221 | 353 | 552 |
| DN600 | 312 | 499 | 779 |
| DN800 | 528 | 845 | 1,320 |
| DN1000 | 817 | 1,307 | 2,043 |
| DN1200 | 1,169 | 1,870 | 2,922 |
F = P × π/4 × D², with D = spigot outside diameter. This is at working pressure — multiply by 1.5 for the test, and add guide friction. The anchors, not the limit studs, must hold it.
Flange Standards and Materials
Pick your pipe’s flange standard, class and size. If the numbers match your flange, our joint bolts straight on — no adapter, no re-drilling.
Check your flange
Standards we drill to
- EN 1092-1 / DINPN6 · PN10 · PN16 · PN25 · PN40 — DIN was replaced by EN 1092-1 with the same drilling; BS 4504 too
- GB/T 9124.1 (PN)PN6 · PN10 · PN16 · PN25 · PN40 (GB/T 9119 plate flanges) — same drilling as EN 1092-1; Class flanges to GB/T 9124.2 = ASME B16.5
- ASME B16.5 / B16.47Class 150 · Class 300 · Series A 26"–60"; AWWA C207 Class D
- JIS B22205K · 10K · 16K · 20K
- AS 2129 / AS 4087Table D · Table E · PN16
- Your drawingGOST, BS 10 or any special drilling; tapped holes on request
Flange material and finish
- Carbon steel Q235 Hot-dip galvanised, zinc plated or painted (blue / black)
- Stainless steel 304: For corrosive environments and seawater areas
- Stainless steel 316L For chemical plants and coastal installations
Installing a Double Flange Expansion Joint
Four steps. The order matters: flanges first, then seal, then lock.

Anchor both sides
Under pressure the joint pushes the pipes apart. Anchors take that force; above ground, fix supports at both ends.

Install at half stroke
Loosen the gland, pull the joint to half its stroke, tighten the gland diagonally, then set the limit nuts.

Keep the pipe on one axis
Put guides close to the joint. It takes axial movement only — never load it off-centre.

Leave the limit nut gap
The gap is the extension still available. Never tighten limit nuts against the flange.
Options
Add these when the job needs them — each one is priced separately.

Stainless steel
Body, spigot, gland and studs in stainless steel, for sea water and chemical plants.

Blue or red epoxy
Epoxy coated inside and out, in blue or red; hot-dip galvanising on request.

Long stroke / custom length
Longer stroke for long pipe runs, or a length made to your gap.

Two drilling standards
One end EN, the other ASME, JIS or AS — for joining old and new equipment.
Why Buy From Our Factory
This is simple steelwork. What decides whether it works on site is the right length, the right drilling and rods sized for the pressure — then the price.

Length and drilling confirmed first
Face-to-face length, setting range and the drilling of both flanges are checked against your drawing and sent back for approval before we cut steel.

Thrust checked, not guessed
Tie studs on our dismantling joints are checked against the pressure thrust at test pressure; for expansion joints we give you the anchor load. Both are in the datasheet.

Pressure tested before coating
Every joint is hydrostatically tested at 1.5 × PN, then blasted and coated

Factory price, quoted the same day
You buy from the production line, not through a trader. Send size, pressure and gap, and get a price the same working day.
Where It’s Installed

Long pipe runs
Between two anchors on water, heating and process lines, it takes the length change from temperature.

Valve lines
Beside valves and pumps that sit on their own supports; makes fitting and removal easier.

Pipe bridges
Where a pipe crosses a river or road between two piers, anchored at each pier.
In Service
Dismantling and expansion joints from our factory, photographed by customers on site.




Double Flange Expansion Joint Price
What you pay depends on a few choices. Send them and we quote the same day.
What changes the price
- Size : DN is the biggest factor
- Pressure class : PN16 needs thicker flanges and bigger studs than PN10
- Body material : Carbon steel, ductile iron or stainless steel
- Finish : Blue or red epoxy, or stainless steel
- Drilling : Standard drilling vs two different standards
- Length : Standard length vs long stroke or custom length
- Quantity : Price breaks at 100/ 200 pcs
Reference price
| Size | Price per piece |
|---|---|
| DN100 | Get today’s price → |
| DN200 | Get today’s price → |
| DN300 | Get today’s price → |
| DN500 | Get today’s price → |
| DN800 | Get today’s price → |
PN16, Q235 steel, NBR gasket, blue epoxy, EXW Gongyi. Prices change with steel costs — send your size and pressure and we quote the same day.
Downloads
Datasheets, drawings and references for submittals.
Control rods
Frequently Asked Questions
What is the difference between an expansion joint and a dismantling joint?
The rods. A dismantling joint has long tie studs locked at every flange, so it is rigid and carries the pressure thrust. This expansion joint has limit studs whose outside nuts sit at the end of the stroke, so it moves — and needs anchors.
How much movement does it take?
Total axial stroke 50 mm (DN65–DN250), 65 mm (DN300–DN700), 130 mm (DN800–DN2400) and 140 mm (DN2600–DN3600). Steel pipe grows about 0.012 mm per metre for every °C — use the calculator above.
Do I need anchors?
Yes, on both sides. Each anchor must hold the pressure thrust shown in the anchor load table, plus guide friction. Above ground, fix supports at both ends.
What do the limit studs do?
They stop the joint pulling apart if an anchor moves or during filling. They are not designed to carry the full pressure thrust.
Can it take lateral or angular misalignment?
No — axial movement only, and it must not be loaded off-centre. Keep the pipe straight with guides. For lateral or angular movement use a rubber expansion joint.
Which gasket for hot water?
EPDM, up to +90 °C. The standard NBR gasket covers −10 to +80 °C. Tell us the highest temperature in the line.
What is the MOQ and lead time?
MOQ 1 pcs. Common sizes ship in 5-7 days; large diameters and special drilling take 15-30 days.
Related Products

Double Flange Expansion Joint
- Type: Limited, VSSJA-2 (B2F)
- Size Range: DN65–DN3600
- Use : Thermal movement between anchors

Single Flange Expansion Joint
- Type : VSSJA-1 (BF), one plain end
- Size Range: DN65–DN3600
- Use : Flange to plain-end pipe

Detachable Dismantling Joint
- Type : VSSJAFC (CC2F), with short pipe
- Size Range: DN65–DN3600
- Use : Pump houses, large valves

Single Sphere Rubber Expansion Joint
- Structure : One rubber arch
- Size Range: DN32–DN3200
- Use : Pump vibration, misalignment

Metal Expansion Joint
- Type : Stainless bellows
- Size Range: Made to order
- Use : Steam, hot oil, high temperature

Flexible Metal Hose
- Type : Braided stainless hose
- Size Range: DN15–DN300
- Use : Pumps, chillers, gas lines
Send Your Size, Pressure and Medium
We reply with a drawing and a price within 24 hours on working days.

Contact Us
Send your size, pressure, medium, flange standard and quantity. This block follows the clean contact layout of your reference page.